All places of work are required to provide adequate technique of escape, and these routes and exits should be properly covered by emergency lighting, so that they may be visible even in an electrical cut. In the BRITISH ISLES these requirements come below the Regulatory Reform (Fire Safety) Obtain 2005, which places a duty within the ‘Responsible Person’ to ensure these measures are developing place.
The nature along with extent of emergency light will vary with different premises, and the time the fact that lighting is required to keep on for could always be between one and 3 hours. The basic function on this is so that there may be enough lighting to get everyone safely out from the building in an catastrophe, but the longer the lighting last the higher quality. In order to guarantee that the lighting is operating properly and able to last if it needs to, the emergency lighting system has to be tested regularly.
Some of the newer systems will allow you to testing themselves, but most buildings will have older emergency lighting which involves manual testing. How this is done relies on the system in position, but the usual method could be to use a special switch which has a ‘fishtail key’ to set-off the lighting.
The best way to organise your testing is usually to be systematic about it and keep a precise record in a logbook. You should carry out different exams at regular intervals, weekly, monthly, six monthly and also annually. Daily checking is encouraged for premises with serviced lighting (emergency lights which stay on all the time). This just ought to be a visual check to guarantee they are all doing work, and deal with any that are not.
A monthly check should include cutting the energy to all lighting, just to make certain all non-maintained bulbs (ones which only can happen in a power cut) are working. If you do not have a testing facility which includes a fish key, you are able to do this through your fuse box.
Every six months it a great idea to cut the power for a minumum of one hour to ensure the actual batteries last long adequate. At least once every year you have to carry out a ‘full discharge test’ , involving cutting off the power and letting the complete system discharge. It is preferable to secure a qualified electrical engineer to start this and check the whole system together. When you carry out a complete discharge test, you should time this so that your premises are not available for the following Twenty four hours, as the batteries could all be drained as well as the emergency lighting therefore not necessarily working.
You should start using a special form to record when you carry out an evaluation. There are forms available online free that you just can download. The form should record the date belonging to the test, the result in the test, any remedial action you’ve taken, and a signature with the person carrying out the test. Your local fire authority has the proper to check whether you are properly testing and maintaining your emergency lighting procedure, so keeping a logbook together with these records in can be very helpful when the following happens.